3. PERIODIC CHECK
3.10 Cleaning/toner recycle section
3.10.1
Replacing the cleaning blade assy
Note
• Be sure to avoid touching the edge section of the cleaning blade assy with bare hands.
• When installing the cleaning blade assy, be sure to apply setting powder to the circumference of
the drum and the cleaning blade, regardless of these parts being new or used ones.
• When setting powder is applied to the drum, be sure to conduct the following operations before
installing the drum unit to the main body.
1) With the charging corona unit removed, rotate the drum 1 full turn (to prevent setting powder
from splashing onto the charging corona unit and the image from getting defective.)
A. Periodically replaced part/cycle
•
Cleaning blade assy
*1
501/421
*2
361
B. Procedure
[2]
44
: Every 250,000 prints *1
: Every 225,000 prints *2
[1]
50gaf2c046na
[1]
50gaf2c047na
Field Service Ver.2.0 Mar. 2009
1.
Remove the developing unit from the main body.
(See P.37)
2.
Open ADU.
(See P.138)
3.
Open the conveyance unit.
(See P.29)
4.
Remove the drum unit from the main body.
(See P.29)
5.
Remove the drum from the drum unit.
(See P.30)
6.
Remove the 2 screws [1] and then remove the
cleaning blade presser plate [2].
7.