MAINTENANCE
2. PERIODIC CHECK
2.1
Maintenance procedure of the paper feed section
Caution
• When connected to the main body, make sure that the power cord of the main body is unplugged
from the power outlet.
2.1.1
Replacing the pick-up rubber and the feed rubber
A. Periodically replaced parts/cycle
•
Pick-up rubber
•
Feed rubber
*1
501/421
*2
361
: Every 500,000 prints (Actual replacement cycle: Every 200,000 prints) *1
: Every 450,000 prints (Actual replacement cycle: Every 200,000 prints) *2
: Every 500,000 prints (Actual replacement cycle: Every 200,000 prints) *1
: Every 450,000 prints (Actual replacement cycle: Every 200,000 prints) *2
2. PERIODIC CHECK