10. SERVICE MODE
10.3.8

Cross Direction Adjustment (Scan Area)

Adjusts the magnification of the image in the main scan direction while in the scan in the platen mode and in the
DF mode.
A. Procedure
1.
"Service Mode screen"
Press [Machine].
2.
"Machine Adjust screen"
Press [Scan Area].
3.
"Scan Area screen"
Press [Cross Direction Adjustment].
4.
"Scan Area (Cross Direction Adjustment) screen"
Press [Test Copy].
5.
"Test Copy screen"
With the test chart set on the original glass or ADF, select A3 (for metric) or 11 x 17 (for inch) paper and
press the Start key.
6.
Press [OK].
7.
Measure the magnification in the main scan direc-
tion with a scale.
Standard value [1]: ± 0.5 % or less (200 ± 1 mm
or less)
8.
"Scan Area screen"
Enter a value through the [+]/[–] or numeric keys and press [Setting].
Setting range: – 5,0 (smaller) to + 5.0% (larger)
1 step = 0.1%
Press [Restore] to return to the value before change.
9.
Repeat steps 4 to 8 until it gets within the standard value.
10.
Press [END].