Field Service Ver.1.0 May. 2008
MAINTENANCE
2.
PERIODIC CHECK
2.1
Maintenance procedure
2.1.1
Replacing the Separation Roller Assy
A. Periodically replaced part/cycle
• Separation Roller Assy : Every 750,000 prints (Actual replacement cycle: Every 300,000 prints) *1
*1
501/421
*2
361
NOTE
• Replace the Separation Roller Assy, Feed Roller and Pick-up Roller at the same time.
B. Procedure
[3]
[5]
[6]
: Every 675,000 prints (Actual replacement cycle: Every 300,000 prints) *2
[2]
[1]
4061f2c001na
[4]
4061f2c002na
[7]
[5]
4061f2c003na
1. Remove the Right Door.
(See P.11)
2. Remove two screws [1] and remove the
Jam Access Cover [2].
3. Remove two screws [3] and remove the
Separation Roller Mounting Plate Assy
[4].
4. Remove two C-rings [5] and the shaft
[6], and remove the Separation Roller
Fixing Plate Assy [7].
NOTE
• Be careful not to lose spring at this
time.
2. PERIODIC CHECK