7.3.4. /EDID
The node and its sub nodes represent all information about EDID management. The node
contains basic methods in connection with EDID emulation such as Copy, Delete or
Emulate EDID. Sub nodes refer to the type of the EDID as follows:
The node structure of Factory, User and Dynamic EDIDs contain the available EDIDs as
sub nodes. The structure of these EDID sub nodes is the same:
For detailed information about EDID memory see section
7.3.5. /MEDIA
MEDIA node contains the available layers on installed modules, such as VIDEO, AUDIO,
UART or IR module. Port and Crosspoint settings are structured in sub nodes with methods
and properties in the nodes of the layers.
7.3.6. /SYS
The node has two sub nodes: LOG and CORE.
/SYS/LOG
Last log events collected from last booting. The structure is the same as for
/MANAGEMENT/LOG.
/SYS/CORE
The node contains properties of MODEX frame; nevertheless its sub nodes contain the
installed modules (B, C, D and E). Signal parameters are listed in the sub nodes.
7.4. Video port and crosspoint settings
Info: Port numbers, commands and responses depend on the modules built in the given MODEX
unit; see the P1..Pn properties under /MEDIA/VIDEO node.
7.4.1. Query the video crosspoint setting
Command format: GET●/MEDIA/VIDEO/XP1.DestinationConnectionList
Response format: pr●/MEDIA/VIDEO/XP1.DestinationConnectionList=<input>:<output>
Legend:
Example:
Page 76 / 113
F:
Factory EDIDs,
U:
User EDID,
D:
Dynamic EDID (The EDID of the monitor last attached to the receiver),
E:
Emulated EDID (List of assigned video ports).
Header:
Valid/Invalid (based on EDID header)
EDID data – in HEX format
Data:
True/False – (based on EDID data)
IsValid:
<input>:
Video input port number
<output>:
Video output port number
> GET●/MEDIA/VIDEO/XP1.DestinationConnectionList
< pr●/MEDIA/VIDEO/XP1.DestinationConnectionList=P2:P3
6.6.1
on page 50.
Section 7. Programmer's reference
Need help?