STARTING SYSTEM - Voltage Converter Relay
VOLTAGE CONVERTER RELAY
(HZJ80and HDJ80) (w/24 V Starter)
LOCATION:
INSPECTION OF VOLTAGE CONVERTER RELAY
1.
INSPECT RELAY CONTINUITY
(a)
(b) Check that there is continuity between terminals 1 -
(c) Check that there is continuity between terminals 1 +
(d) Check that there is no continuity between terminals
If continuity is not as specified, replace the relay.
2.
INSPECT RELAY OPERATION
(a) Apply battery voltage across terminals e and g.
(b) Using an ohmmeter, check that there is continuity
(c)
(d) Check that there is no continuity between terminals
If operation is not as specified, replace the relay.
In the engine compartment on the left side.
Using an ohmmeter, check that there is continuity
between terminals e and g.
and E.
and 2 + .
1 - and 2 + .
between terminals 1 - and 2 + .
Check that there is no continuity between terminals
1+ and 2 + .
1 - and E.