Procedure
1. Log on to ACLI in Global Configuration command mode.
2. At the command prompt, enter the following command:
Variable definitions
The following table describes the parameters for the clock time-zone command.
zone
hours
minutes
no

Setting or disabling daylight savings time

Set the daylight savings time with start and end dates, or disable the daylight savings time
feature.
Procedure
1. Log on to ACLI in Global Configuration command mode.
2. At the command prompt, enter the following command:
Getting Started
[no] clock time-zone <zone> <hours> <minutes>
Variable
[no] clock summer-time <zone> [date {<day> <month> <year>
<hh:mm>} {<day> <month> <year> <hh:mm>}] [<offset>]
Value
Specifies time zone acronym that can be
displayed when showing system time; for
example, EST for Eastern Standard Time.
RANGE: Up to 4 characters
Specify the hours difference from UTC.
RANGE: —12 to + 12
Optional minutes difference from UTC.
RANGE: 0–59
Disables the clock time zone feature