TROUBLESHOOTING
Lamp Suddenly
Turns Off
Flicker, Shadows
Or Dimness
LampLOC
Does Not
Seem to Work
LiteLOC
Does Not
Seem To Work
5.3

Ethernet

5.4

Displays

Symptom
CAUSE/REMEDY:
5-2
Roadie 25K User's Manual
'
1. Try increasing the lamp power.
2. The DMDs in the projection head may be overheated (this also triggers a
message on the LCD status display window).
3. An interlock, such as an open lamp door or inadequate airflow to the extractor,
may be interrupting lamp function.
4. Replace the lamp.
'
1. LampLOC
may need re-adjustment—see 3.9, Working With the Lamp.
2. LampLOC
may be in the middle of its adjustment. Wait until completed.
3. Increase lamp power, if possible.
'
1. Try adjusting lamp positions individually in the LampLOC submenu—display a
Full White test pattern and watch the "Intensity" reading for changes indicating
lamp movement.
2. If the motors do not seem to respond, manual adjustment may be required.
Danger. Qualified service technician only.
'
1. Make sure "Intensity" is selected in the Lamp menu. Other lamp modes disable
LiteLOC
.
2. If the lamp power has increased to its maximum in order to maintain a LiteLOC
setting, LiteLOC
menu indicate that the lamp power has reached this "over-drive" state, either
reduce your LiteLOC
1. Make sure the Ethernet settings are valid for your site—all network devices
should have the same subnet mask and unique IP addresses.
2. Make sure to save any address change, and re-boot (cycle power) to implement.
3. Make sure the projector is connected to the network before changing its IP
address.
4. If you still have trouble establishing communications with a projector added to an
existing Ethernet network, the projector's IP address is likely in conflict with
another address already in use. Contact your network administrator.
Blank screen, no display of image...
'
1. Confirm all power connections are still OK.
2. Make sure the lens cap has been removed.
3. Make sure the shutter is OPEN.
4. Make sure there is not a full black test pattern selected for display—press
to access test patterns, then cycle patterns with
5. Is the input selected? Check connections.
is automatically terminated. If the values shown in the Lamp