Input/Output Signal Of The External Signal - SATO S84ex Operator's Manual

Hide thumbs Also See for S84ex:
Table of Contents

Advertisement

8 Appendix

8.5 Input/Output Signal of the External Signal

This section provides additional information about setting the pin number of the input/output signal in the
INPUT SIGNAL/OUTPUT SIGNAL
Setting Conditions
Signal Name
PRINT START
Reprint
FEED
LABEL NEAR
Paper End
Ribbon End
MACHINE ERR
PRINT END *
ONLINE
RIBBON NEAR
1
You cannot select "-" for the PRINT END output signal.
*
Note
• When multiple errors are allocated to one pin, the signal is output when one of the errors occurs.
• All errors need to be released in order to switch the signal output back to normal.
314
S84-ex/S86-ex Operator Manual
screen of the advanced mode menu.
Input/Output
(Default Value)
Input
Input
Input
Input
Output
Output
Output
1
Output
Output
Output
Pin No.
Overlapping
20
Not Allowed
8
Not Allowed
21
Not Allowed
7
Not Allowed
17
Allowed
16
Allowed
4
Allowed
5
Not Allowed
6
Allowed
18
Allowed
Available Pin No.
20, 8
21, 7, -
Note: When "-" is selected, the
function is disabled.
4, 5, 6, 16, 17, 18, -
Note: When "-" is selected, there is
no output.

Advertisement

Table of Contents
loading

This manual is also suitable for:

S86ex

Table of Contents