9.4

Disassembly and Replacement

[A] Bypass pickup roller
(1)
Remove 1 clip.
(2)
Pull out the shaft and take off the bypass
pickup roller.
[B] Bypass feed unit
(1)
If the ADU is not installed, take off the right
front hinge cover, the right rear hinge cover
and the bypass upper cover (
Right front hinge cover",
rear hinge cover",
upper cover").
If the ADU is installed, take off the ADU (
P.15-10 "[A] Automatic Duplexing Unit
(ADU)").
(2)
Remove 1 spring.
(3)
Disconnect the connector of the bypass feed
clutch.
© 2004 - 2008 TOSHIBA TEC CORPORATION All rights reserved
P.2-38 "[P]
P.2-39 "[Q] Right
P.2-39 "[R] Bypass
9 - 13
04/09
Clip
Bypass pickup roller
Fig. 9-9
Connector
Fig. 9-10
e-STUDIO200L/202L/203L/230/232/233/280/282/283
PAPER FEEDING SYSTEM
Shaft
9
Spring