[G] Cleaning roller
(1)
Take off the pressure roller
(
P.13-14 "[E] Fuser roller").
(2)
Remove 2 screws and take off the cleaning
unit.
(3)
Press down the holder and take off the
cleaning roller.
[H] Thermistor
(1)
Place the fuser unit upside down.
(2)
Release the latch and take off the harness
cover.
e-STUDIO200L/202L/203L/230/232/233/280/282/283
FUSER UNIT
Cleaning unit
Holder
© 2004 - 2008 TOSHIBA TEC CORPORATION All rights reserved
13 - 16
Fig. 13-20
Cleaning roller
Fig. 13-21
Harness cover
Fig. 13-22