(5)
Remove 2 screws on both ends of the doctor
sleeve and remove 2 coil springs.
Note:
When the screws on both ends of the doctor
sleeve are removed, be sure to adjust the
doctor sleeve gap (0.45±0.05 mm) after
assembling.
(Refer to Service Handbook Chap. 3.9)
(6)
Remove 1 screw and plate spring.
(7)
Remove 1 screw and take off the polarity
adjustment lever.
Note:
Make a note of the position where the polar-
ity adjustment lever is pointing. (Mark the
position if needed.) When reassembling,
match the polarity adjustment lever with the
previously marked position on the scale.
(8)
Remove 2 screws and take off the bracket.
e-STUDIO200L/202L/203L/230/232/233/280/282/283
DEVELOPMENT SYSTEM
Coil spring
Screw
Connector