[H] Bypass tray
(1)
Take off the bypass unit
(
P.9-17 "[G] Bypass unit").
(2)
Disconnect 1 connector. Remove 2 screws
and take off the bypass tray.
Note:
The bypass tray is removable without taking
off the bypass unit from the equipment.
(3)
Pull out the hinge assembly from the bypass
tray.
[I]
Paper size detection sensor
(1)
Take off the bypass tray.
(
P.9-18 "[H] Bypass tray").
(2)
Remove 3 screws and take off the bypass
tray upper cover.
e-STUDIO200L/202L/203L/230/232/233/280/282/283
PAPER FEEDING SYSTEM
Bypass tray
Bypass tray
upper cover