Field Service Ver.2.0 Jan. 2007
6.1.3
Developing unit
(1) Parts not allowed to be removed
•
2 attaching screws of the developer restriction blade
•
1 fixing screw of the magnet adjustment plate
•
Ds adjustment screws
Developing unit at 2 places (inside the cover)
[4]
[1]
Developer restriction blade
[2]
Developing roller
[3]
Screws not allowed to be removed
[4]
Magnet adjustment plate
(2) Reason for prohibition
Each of the developer restriction blade and the magnet adjustment plate is used to determine the height of
developer on the developing roller. And the Ds adjustment screws are also used to determine the distance
between the drum and the developing roller. These parts are adjusted to an appropriate value in advance.
Therefore do not remove these attaching screws and fixing screws.
Confidential – for internal use only, do not distribute
[5]
[3]
[6]
[2]
[5]
Screws not allowed to be removed
(Ds adjustment screws)
[6]
Screws not allowed to be removed
6. OTHERS
[1]
50gaf2c140na
137