Field Service Ver.2.0 Jan. 2007
MAINTENANCE
2.
PERIODIC CHECK
2.1
Maintenance procedure
2.1.1
Replacing the Separation Roller Assy
A. Periodically replaced part/cycle
• Separation Roller Assy: Every 750,000 prints (Actual replacement cycle: Every 300,000
prints)
NOTE
• Replace the Separation Roller Assy, Feed Roller and Pick-up Roller at the same time.
B. Procedure
[1]
[4]
[3]
[7]
Confidential – for internal use only, do not distribute
1. Remove the Right Door.
[2]
2. Remove two screws [1] and remove the
4061f2c201na
3. Remove two C-rings [3] and the shaft
[5]
NOTE
• Be careful not to lose spring at this
time.
[3]
4061f2c202na
4. Remove the C-ring [6], the Guide [7],
[8]
[6]
4061f2c203na
2. PERIODIC CHECK
(See P.11)
Separation Roller Mounting Plate Assy
[2].
[4], and remove the Separation Roller
Fixing Plate Assy [5].
and remove the Separation Roller Assy
[8].
3