Field Service Ver.2.0 Jan. 2007
3.15.3
Replacing the fusing web
A. Periodically replaced part/cycle
•
Fusing web
*1
500/420
*2
360
B. Procedure
[4]
[1]
[5]
[2]
Confidential – for internal use only, do not distribute
: Every 250,000 prints *1
: Every 225,000 prints *2
[2]
[3]
50gaf2c092na
[1]
50gaf2c093na
1.
Remove the fusing unit.
(See P.80)
2.
Remove the fusing claw assy.
(See P.82)
3.
Remove the screw [1].
4.
Remove the 5 screws [2].
5.
Apply pressure from the inside of the ducts [3] at 2
places to release the lock and remove the fusing
web [4].
Note
• When installing the fusing web, be sure to
install the screw [1] first.
Note
• When installing the fusing web, be sure to
insert the projections [1] at 2 places into the
positioning holes [2].
3. PERIODIC CHECK
85
1