Field Service Ver.2.0 Jan. 2007

10.7 State Confirmation

10.7.1

Sensor Check

This machine is provided with an input/output check function as a self-diagnostic function. For the sensor check
(input check), the state confirmation of each signal can be made.
A. Procedure
1.
"Service Mode screen"
Press [State Confirmation].
2.
"State Confirmation screen"
Press [Sensor check].
3.
"Sensor Check screen"
Press [Check Code] and, when entering the sensor check code in 3 digit through the copy count setting
button, a state (ON/OFF or value) is displayed in the Result area.
4.
For the multi mode, press [Multi Code] and enter a three-digit multi code through the copy count setting
key.
5.
When conducting the sensor check of other signal sources, repeat steps 3 to 4.
B. List of sensors
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
10
1
2
3
4
5
6
7
11
1
2
3
4
5
6
Confidential – for internal use only, do not distribute
TCRS
Drum temperature
TCRS
TCR sensor
TCRS
TCR sensor
TH1
Thermistor /1
TH2
Thermistor /2
IDCS
IDC sensor
HUMS
Humidity sensor
VR1
Paper size VR/BP (bypass)
PS18
paper empty sensor /BP (bypass)
PS23
Lift sensor (bypass)
Connect detection signal (bypass)
PS19
Paper size sensor /BP1 (bypass)
PS20
Paper size sensor /BP2 (bypass)
PS21
Paper size sensor /BP3 (bypass)
PS22
Paper size sensor /BP4 (bypass)
PS5
Paper empty sensor /1
PS9
Near-empty sensor /1
PS6
Upper limit sensor /1
PS8
Tray set sensor /1
PS10
Paper size sensor /Rr1
PS11
Paper size sensor /Fr1
Name
10. SERVICE MODE
Display and signal source
ON
OFF
0 to 255 *1
No paper
Paper
Up position
Down position
Connection
Non-connection
Paper
No paper
No paper
Paper
Near-empty
Non-near-empty
Upper limit
Not at upper limit
Set
Not set