TABLE A-10
Error Message
Host address for
interface_name must be
internet address.
I/O bus device tree not
built.
minor_walk: failed to
build net leaf.
minor_walk: failed to
build non-net leaf.
Partition partition_name does
not have parent.
82
Sun Enterprise 10000 Dynamic Reconfiguration User Guide • February 2000
System Exploration Error Messages (Continued)
Probable Cause
The file that is needed to test each
active network device may have a
corrupted value or an incorrect
network address. While the network
devices are examined, each active
network device is tested to
determine if it is the primary
network interface for the domain.
The DR daemon will not allow the
detachability test to pass if it cannot
determine which active network
device is the primary network
interface for the domain.
This error message continues added
information about the DR Error:
device tree not built error
message, in which the libdevinfo
API failed to build the device tree for
the system board.
This error message continues added
information about the DR Error:
device tree not built error
message, in which the libdevinfo
API failed to build the device tree for
the system board. This message
indicates that the libdevinfo API
at least started to look at the minor
devices for a network leaf node.
This error message continues added
information about the device tree
not built error message,
indicating that the libdevinfo API
at least started to look at the minor
devices for a non-network leaf node.
The device tree is in error because it
includes a disk partition that does
not have a parent device, such as the
disk to which the partition belongs.
Suggested Action
Make sure that the hostname file
for the primary network
interface contains an IP address
in the proper form (that is,
xxx.xxx.xxx.xxx). The file is
named
/etc/hostname.interface_name,
where interface_name is the
interface named in the error
message.
See the DR Error: device
tree not built error
message.
See the DR Error: device
tree not built error
message.
See the DR Error: I/O bus
device tree not built
error message.
A device could be bad, or a
reboot may be necessary. If this
error continues to appear, report
the error to your Sun service
representative, providing as
much information from the
system logs as possible.