To Attach a Board By Using dr(1M)
Note – The following procedure explains how to attach a board by using dr(1M)
with SSP version 3.1, or higher. If you are using SSP version 3.0, refer to a previous
version of the Dynamic Reconfiguration User's Guide.
Before you perform the following steps, read "Attaching a System Board" on page
17. The process of attaching a board is very similar whether you use Hostview or
dr(1M). The basic concepts are not repeated in this section.
The dr(1M) shell was introduced in Chapter 1. A quick reference guide is available
in the dr(1M) application by using the help command.
1. Set SUNW_HOSTNAME to the appropriate domain by using the
domain_switch(1M) command.
% domain_switch domain_name
2. Use the dr(1M) command in an SSP Window to bring up the dr(1M) prompt.
In the following example, the target domain is called xf3.
% dr
Checking environment...
Establishing Control Board Server connection...
Initializing SSP SNMP MIB...
Establishing communication with DR daemon...
xf3: Domain Status - Summary
BOARD #: 0 1 2 5 6 8 9 10 11 13 physically present.
BOARD #: 4 7 being used by the domain.
dr>
Chapter
23
Need help?
Do you have a question about the Sun Enterprise 10000 Dynamic and is the answer not in the manual?