TABLE A-7
Error Message
DR Error: Cannot abort
attach. Board ineligible
for further DR operations.
dr_attach: failure
executing A3000 hot_add
script . . . error message
initiate_attach_board:
already init-attached
DR Error:
complete_attach_board:
invalid board state
DR Error:
initiate_attach_board:
invalid board state
DR Error: Some devices not
attached. Examine the host
syslog for details . . .
errno_description
Attach-Related Failure Error Messages (Continued)
Probable Cause
The board entered the FATAL state
after the abort command was issued,
causing the abort operation to fail and
the board to be lost from the system.
The Sun™ StoreEdge™ A3000
hot_add script is executed directly
after a DR Attach operation. If the
script exists, but it cannot be executed,
the error message explains why.
You attempted to initiate the attach of
a board that was already initiated.
You tried to initiate an Attach
operation on a board that is not
eligible—the board is not in the Init-
Attach state awaiting attachment to
the domain.
You tried to initiate an Attach
operation on a board that is not
eligible—the board is not in the
PRESENT state awaiting attachment to
the domain.
Some of the devices were not
configured into the domain.
Suggested Action
Reboot the domain.
If you are not using, nor plan
to use, A3000 devices, you
can rename the script so that
it will not be found.
Go to the Complete Attach
window and continue the
attach process.
Wait for the board to enter
the Init-Attach state. Only
then can the Attach operation
be aborted.
Wait for the board to enter
the Init-Attach state. Only
then can the Attach operation
be aborted.
Look at the system logs for
more details about what
devices were not configured
into the domain and why
they were not configured.
Some devices on the board
may not be supported by the
operating environment or by
the DR feature. You should
blacklist unsupported
devices.