TABLE A-12
Error Message
WARNING: board board_number
not checked for unsafe
devices.
DR Error: unsafe_devices:
libdevinfo failed.
DR Error:
create_ctlr_array: count
mismatch [internal error]
Unsafe-Device Query Error Messages (Continued)
Probable Cause
While the DR daemon was examining
the system boards for unsafe devices,
the daemon encountered a failure that
prevented it from examining one of the
system boards (board_number). This
error message may be indicative of a
more serious problem.
The DR daemon cannot determine the
names of unsafe major devices because
it cannot use the libdevinfo API.
This API must be used to search the
device tree for the names of all of the
unsafe major devices.
Communication protocol was
breached over the existence of AP
controllers. To the AP librarian, the
domain has a certain number of AP
controllers. However, to the DR
daemon, the domain has a different
number of AP controllers.
Suggested Action
You may have to stop and
restart the DR daemon to
recover the domain from this
error. Check the size of the
DR daemon. If should be
between 300- and 400-Kbytes.
If it is not within this range,
stop the daemon, then restart
it. If you cannot recover the
domain from this error, you
should report this error to
your Sun service
representative, providing as
much information from the
system logs as possible.
Make sure that the domain
contains the correct version
of the libdevinfo API and
that the domain does not
contain version mismatches
between any of the DR
daemon's libraries, the
operating environment on
the domain, or the daemon
itself. If you cannot
determine the cause of this
error, report it to your Sun
service representative,
providing as much
information from the system
logs as possible.
Check to determine the
correct amount of AP
controllers in the domain,
and correct the error. Also,
check the size of the DR
daemon. It should be
between 300- and 400-Kbytes.
If it is not within this range,
stop the daemon then restart
it.