03031000-2E12 Defective Paper Release Lever; 03060A00-2E1B Roll Media End Error; 03130031-260E Gap Detection Error - Canon imageprograf ipf700 Service Manual

Hide thumbs Also See for imageprograf ipf700:
Table of Contents

Advertisement

If continuity of the cable between the carriage relay PCB and the main controller PCB is abnormal, replace the
cable.
7) Replace the main controller PCB.

6.1.4.9 03031000-2E12 Defective paper release lever

<Cause>
The pressure release switch detected that the paper release lever was open with the upper cover locked.
<Probable fault location>
Operation method, pressure release switch, or main controller PCB
<Countermeasure>
1) Operation check
Close the paper release lever fully.
2) Visual check
If the paper release lever is damaged or deformed, replace it.
3) Pressure release switch
Select [SERVICE MODE]>[I/O DISPLAY] to check for normal operation. If the operation is abnormal, replace
the pressure release switch.
4) Cable continuity check
If continuity of the cable between the pressure release switch and the main controller PCB is abnormal, replace
the cable.
5) Replace the main controller PCB.

6.1.4.10 03060A00-2E1B Roll media end error

<Cause>
During printing or roll media feed, the media sensor detected the end of the roll media.
<Probable fault location>
Roll media, media sensor, or main controller PCB
<Countermeasure>
1) Roll media
If roll media is used up, load new roll media.
2) Media sensor
Select [SERVICE MODE]>[I/O DISPLAY] to check for normal operation. If the operation is abnormal, replace
the media sensor.
3) Cable continuity check
If continuity of the cable between the media sensor and the main controller PCB is abnormal, replace the cable.
4) Replace the main controller PCB.

6.1.4.11 03130031-260E Gap detection error

<Cause>
A detection error occurred due to damaged hardware, uncorrected gap, or damaged correction data.
<Probable fault location>
Multi sensor or main controller PCB
<Countermeasure>
1) Cable continuity check
If continuity of the cable between the multi sensor and the main controller PCB is abnormal, replace the cable.
2) Replace the multi sensor.
3) Replace the main controller PCB.