Value Range
2–5 digits
Feature Manual References
2.4.1 Auto Configuration (APT/DPT Integration Only)
Operator Transfer Sequence
Specifies the sequence for transferring calls to an operator's extension.
Default
FX
Value Range
Max. 16 digits consisting of 0–9,
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
,: Dial Pause (default 1 s)
;: Dial Pause (default 3 s)
X: Extension Dialing
0–9,
, #: Dial Code
Extension Transfer Sequence
Specifies the sequence for transferring calls to any extension except an operator's extension.
Default
FX
Value Range
Max. 16 digits consisting of 0–9, , # and special codes
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
,: Dial Pause (default 1 s)
;: Dial Pause (default 3 s)
X: Extension Dialing
0–9,
, #: Dial Code
Alternate Extension Transfer Sequence
Specifies the sequence for transferring calls to extensions in the Alternate Extension Group.
Default
FX
Value Range
Max. 16 digits consisting of 0–9,
Document Version 3.0 2010/06
, # and special codes
, # and special codes
2.5.4 Parameters
Programming Manual