1.9.7 Utility—System Initialize/Restart
Value Range
HH:MM (HH: Hour, MM: Minute)

HDD Auto Stand-by Mode

Specifies whether HDD Auto Stand-by Mode is enabled or disabled. This option is only available when the
connected VPS is a KX-TVA200.
Default
Enable
Value Range
Disable, Enable

HDD Auto Stand-by Delay Time

Specifies the length of time that the VPS waits before activating HDD Auto Stand-by Mode. If the HDD is not
accessed for the length of time set here, the HDD goes into standby mode. This option is only available when
the connected VPS is a KX-TVA200.
Default
15 min
Value Range
0 min–21 min, 30 min/60 min
1.9.7 Utility—System Initialize/Restart
The System Initialize/Restart is used to restart the VPS. There are 2 methods as follows:
a.
Initialize System: clears all voice data except the installed system guidance, and returns all system
parameters to their default settings. The System Administrator has to specify the following parameters
before initializing the system:
Mailbox No. Length
System Manager's Mailbox No.
Message Manager's Mailbox No.
b.
Restart System: restarts the system. The VPS is not initialized.
Follow the steps below to initialize or restart the VPS:
1.
Click Utility in the menu bar.
2.
Select System Initialize/Restart.
Initialize System
1.
Select Initialize System.
(You can click the icon in the toolbar instead of step 1 and 2.)
2.
Specify the mailbox number length, the System Manager's mailbox number, and the Message
Manager's mailbox number.
Note
The mailbox numbers assigned to the System Manager and Message Manager cannot begin
with "0".