Universal Serial Bus (USB) port problems

Use this information to USB port problems.
Table 21. Universal Serial Bus (USB) port problems and actions
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
A USB device does not work.

Video problems

Use this information to solve video problems.
See "Monitor and video problems" on page 89.

Solving power problems

Use this information to solve power problems.
About this task
Power problems can be difficult to solve. For example, a short circuit can exist
anywhere on any of the power distribution buses. Usually, a short circuit will
cause the power subsystem to shut down because of an overcurrent condition. To
diagnose a power problem, use the following general procedure:
Procedure
1. Turn off the server and disconnect all power cords.
2. Check for loose cables in the power subsystem. Also check for short circuits, for
3. Check for any errors indicated by the operator information panel or LCD
4. If the check log LED on the operator information panel is lit, check the IMM
Action
1. Make sure that:
v The correct USB device driver is installed.
v The operating system supports USB devices.
2. Make sure that the USB configuration options are set correctly in the Setup
utility (see "Using the Setup utility" on page 40 for more information).
3. If you are using a USB hub, disconnect the USB device from the hub and
connect it directly to the server.
example, if a loose screw is causing a short circuit on a circuit board.
operating panel assembly (see "Operator information panel" on page 20
or"LCD operating panel assembly" on page 21 ).
event log for faulty Pwr rail and complete the following steps. Table 22 on page
102 identifies the components that are associated with each Pwr rail and the
order in which to troubleshoot the components.
a. Disconnect the cables and power cords to all internal and external devices.
Leave the power-supply cords connected.
b. For Pwr rail 1 error, complete the following steps:
1) (Trained technician only) Replace the system board.
2) (Trained technician only) Replace the microprocessor.