IBM System x3550 M5 Type 5463 Installation And Service Manual page 347

Table of Contents

Advertisement

80010701-1002ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(PCI 2 Amb Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011002ffff or 0x800107011002ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Server Features and
specifications for more information).
3.
Make sure that the heat sink for microprocessor n.
4.
(Trained technician only) Replace system board.
RR PCI2 Amb Temp :
80010701-1003ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(PCI 3 Amb Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011003ffff or 0x800107011003ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Server Features and
specifications for more information).
3.
Make sure that the heat sink for microprocessor n.
4.
(Trained technician only) Replace system board.
RR PCI3 Amb Temp :
80010701-1002ffff • 80010701-1003ffff
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
331