IBM System x3550 M5 Type 5463 Installation And Service Manual page 351

Table of Contents

Advertisement

80010701-2d01ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(PCH Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107012d01ffff or 0x800107012d01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
2.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010701-3701ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(Ambient Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107013701ffff or 0x800107013701ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010701-2d01ffff • 80010701-3701ffff
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
335

Advertisement

Table of Contents
loading

Table of Contents