IBM System x3550 M5 Type 5463 Installation And Service Manual page 361

Table of Contents

Advertisement

80010b01-1003ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (PCI 3 Amb Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011003ffff or 0x80010b011003ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-1301ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (PSU 1 Amb Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011301ffff or 0x80010b011301ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-1401ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (CPU1 VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011401ffff or 0x80010b011401ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-1003ffff • 80010b01-1401ffff
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
345