IBM System x3550 M5 Type 5463 Installation And Service Manual page 345

Table of Contents

Advertisement

80010204-1d08ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (Fan
8A/8B Tach)
Explanation: This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d08ffff or 0x800102041d08ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010701-0f01ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(REAR BP Temp A)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010f01ffff or 0x800107010f01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
2.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.