80070128-2e01ffff
Sensor [SensorElementName] has transitioned from normal to non-critical state. (ME Recovery)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701282e01ffff or 0x800701282e01ffff
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
User response: None
80070201-0301ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 1
OverTemp)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702010301ffff or 0x800702010301ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Features and specifications
for more information).
3.
Make sure that the heat sink for microprocessor n is installed correctly.
4.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
80070128-2e01ffff • 80070201-0301ffff
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
353