IBM System x3550 M5 Type 5463 Installation And Service Manual page 372

Table of Contents

Advertisement

80070208-0a02ffff • 8007020d-2582ffff
2.
Use the IBM Power Configurator utility to ensure current system power consumption is under limitation. For
more information and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/
powerconfig.html.
3.
Replace power supply n. (n = power supply number)
80070208-0a02ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (PS 2 Therm
Fault)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702080a02ffff or 0x800702080a02ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-supply fan.
2.
Use the IBM Power Configurator utility to ensure current system power consumption is under limitation. For
more information and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/
powerconfig.html.
3.
Replace power supply n. (n = power supply number)
8007020d-2582ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (RAID Vol
State)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020d2582ffff or 0x8007020d2582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: None
356
IBM System x3550 M5 Type 5463: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents