IBM System x3550 M5 Type 5463 Installation And Service Manual page 346

Table of Contents

Advertisement

80010701-0f02ffff • 80010701-1001ffff
80010701-0f02ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(REAR BP Temp B)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010f02ffff or 0x800107010f02ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
2.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010701-1001ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
(PCI 1 Amb Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011001ffff or 0x800107011001ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Server Features and
specifications for more information).
3.
Make sure that the heat sink for microprocessor n.
4.
(Trained technician only) Replace system board.
RAID Amb Temp : RR PCI1 Amb Temp :
330
IBM System x3550 M5 Type 5463: Installation and Service Guide

Advertisement

Table of Contents
loading