3.
Reconnect the connector (J47) on the DC controller PCA.
4.
Replace the fuser motor.
59.00.40 Error To continue turn off then on
Description
A fuser motor rotational error has occurred.
Recommended action
1.
Turn the product off and then on.
2.
Perform the fuser motor component test in the
3.
Reconnect the connector (J47) on the DC controller PCA.
4.
Replace the fuser motor.
59.05.50 Error To continue turn off then on
Description
The product experienced a drum motor startup error.
Recommended action
1.
Perform the drum-motor component test in the
2.
Use the disable toner cartridge check and run the drum motor component test with the toner
cartridge removed. If the test passes, replace the toner cartridge. If the test fails, replace the drum
motor.
3.
If the product was previously serviced, check the connector at the drum motor assembly and the
DC controller. See the circuit diagram for details.
59.05.60 Error To continue turn off then on
Description
The product experienced a drum motor rotation error.
Recommended action
1.
Perform the drum-motor component test in the
2.
Use the disable toner cartridge check and run the drum motor component test with the toner
cartridge removed. If the test passes, replace the toner cartridge. If the test fails, replace the drum
motor.
3.
If the product was previously serviced, check the connector at the drum motor assembly and the
DC controller. See the circuit diagram for details.
358
Chapter 2 Solve problems
Troubleshooting
menu.
Troubleshooting
menu.
Troubleshooting
menu.