Recommended action
1.
Turn the product off and then on.
2.
Verify that the connector (J63) on the DC controller PCA and the sensor (J400) are connected
correctly and undamaged.
3.
If the error persists, replace environmental sensor.
58.00.04 Error To continue turn off then on
Description
The low-voltage power supply is defective.
Recommended action
1.
Turn the product off and then on.
2.
Check the connectors (J31 and J32) on the DC controller PCA.
3.
If the error persists, replace the low voltage power supply.
59.00.00 Error To continue turn off then on
Description
A paper path malfunction error has occurred.
Recommended action
Turn the product off then on.
59.00.20 Error To continue turn off then on
Description
A motor rotation error has occurred.
Recommended action
Turn the product off and then on.
59.00.30 Error To continue turn off then on
Description
A fuser motor startup error has occurred.
Recommended action
1.
Turn the product off and then on.
2.
Perform the fuser motor component test in the
ENWW
Troubleshooting
menu.
Tools for troubleshooting