Tray 5 paper size sensor (PS3304)
1.
Remove Tray 5 from the HCI.
2.
In the tray cavity, press and hold the tray presence switch (callout 1), and then lift the paper size
sensor lever (callout 2).
Figure 2-38
3.
Check the control-panel display for sensor response.
4.
If there is no response, replace the auto-close assembly.
ENWW
Tray 5 paper size sensor
1
2
Tools for troubleshooting
179