Vlan Frame Type Command; Vlan Cpu Show Command; Figure 136 Vlan Frame Type Command Example - ZyXEL Communications IES-1248-51 User Manual

Adsl+ ip dslam
Hide thumbs Also See for IES-1248-51:
Table of Contents

Advertisement

1 An untagged frame comes in from the LAN.
2 The IES-1248-51 checks the frame's source MAC address against the MAC filter.
3 The IES-1248-51 checks the PVID table and assigns a VID and IEEE 802.1Q priority.
4 The IES-1248-51 ignores the port from which the frame came, because the IES-1248-51
does not send a frame to the port from which it came. The IES-1248-51 also does not
forward frames to "forbidden" ports.
5 If after looking at the SVLAN, the IES-1248-51 does not have any ports to which it will
send the frame, it drops the frame.

42.4.5 VLAN Frame Type Command

Syntax:
ras> switch vlan frametype <portlist> <all|tag>
where
<portlist>
<all|tag>
This command sets the specified DSL ports to accept VLAN tagged Ethernet frames, or both
tagged and untagged Ethernet frames.
Note: The IES-1248-51 accepts both tagged and untagged incoming frames on the
Ethernet ports.
The following example sets the IES-1248-51 to accept only VLAN tagged Ethernet frames on
DSL port 3.

Figure 136 VLAN Frame Type Command Example

ras> switch vlan frametype 3 tag

42.4.6 VLAN CPU Show Command

Syntax:
ras> switch vlan cpu show
Chapter 42 IEEE 802.1Q Tagged VLAN Commands
You can specify a single DSL port <1>, all DSL ports <*> or a
=
list of DSL ports <1,3 >. You can also include a range of DSL
ports <1,5,6~10>.
Use
to have the specified port(s) accept only incoming
=
tag
Ethernet frames that have a VLAN tag.
Use
to have the specified port(s) accept both tagged and
all
untagged incoming Ethernet frames.
IES-1248-51 User's Guide