Table 72 Log Messages (continued)
LOG MESSAGE
External alarm is
released.
FAN RPM DOWN: dev:
<id> Limit:N value:N!
FAN RPM OK: dev: <id>
Limit:N value:N!
FAN RPM OVER: dev:
<id>
Limit:N value:N!
Incorrect Password!
Session Begin!
Session End!
Sync with timeserver
<ip> failed!
Sync with timeserver
<ip> successful!
Received File <file>!
Received Firmware
Checksum Error!
Received Firmware
Invalid!
Received Firmware Size
too large!
THERMO LOW
VOLTAGE:
dev: <id> limit:
<threshold> value:
<voltage>!
THERMO LOW
TEMPERATURE: dev:<id>
threshold:<threshold>(
degree C)
value:<temp>(degree
C)!
Chapter 39 Command Examples
TYPE
DESCRIPTION
An external alarm is over and the input has returned to a normal state.
INFO
A fan's RPM went too low.
WARN
<id> 1=Fan 1, 2=Fan 2, 3=Fan
Limit - minimum (low) fan (RPM)
value - the measured fan RPM
A fan's RPM returned to the normal range.
INFO
<id> 1=Fan 1, 2=Fan 2, 3=Fan 3
Limit - maximum (high) or minimum fan (RPM) that had been breached
value - the measured fan RPM
A fan's RPM went too high.
WARN
<id> 1=Fan 1, 2=Fan 2, 3=Fan 3
Limit - maximum (high) fan (RPM)
value - the measured fan RPM
Someone attempted to use the wrong password to start a console, telnet or
WARN
FTP session (see the <process> field for the type of session).
A console, telnet or FTP session has begun (see the <process> field for the
INFO
type of session).
A console telnet or FTP session has terminated (see the <process> field for
INFO
the type of session).
The device was not able to synchronize the time with the time server at the
WARN
listed IP address.
The device synchronized the time with the time server at the listed IP
INFO
address.
A file was uploaded to the IES-1248-51 by FTP.
INFO
<file> - received file's name
A checksum error was detected during an attempted FTP firmware upload.
WARN
Someone attempted to upload a firmware file with a wrong identity via FTP.
WARN
The file size was too large with an attempted FTP firmware upload.
WARN
The device's voltage went above the accepted operating range..
WARN
<id> 1=1.0v, 2=1.8v, 3=3.3v, 4=24v
<threshold> - voltage limit
<voltage> - voltage of the DC power when logged
The temperature was too low at one of the temperature sensors.
WARN
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged
IES-1248-51 User's Guide