2.1 Making Pre-Checks

2.1.1 Checking Installation Environment

iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
The followings are the condition for installation environment.
It is better to see the planned location of installation before carrying the host machine in the user site.
1) The host machine can singly connect to the outlet of rated +/-10V, 15A or more.
2) Temperature and humidity is within the following range. Especially avoid the close location to faucet, water heater, humidifier and refrigerator.
<Environment zone assured>
[A] Zone A: Satisfies all the conditions of the standard image quality and paper feed performance.
[B] Zone B: Inferior to Zone A in terms of the standard image quality and paper feed performance, or may not apply.
[C] Zone C: Problems associated with safety, malfunctions, or incorrect message display do not occur, but image quality and paper feed performance are not
guaranteed.
3) Avoid fire, dusty place and the location where ammonia gas is generated. Also, if the host machine receives direct sunlight at installation location, it is recom-
mended to put curtains on the window.
4) The ozone amount that is generated during operation with the host machine does not cause a hazard to human health; however, its odor may be recognized if the
host machine is used for many hours in the poor ventilated location. Thus, provide adequate ventilation to keep the operation environment comfortable.
5) Make sure that the foot of the host machine does not float, and also, the host machine is leveled.
6) Allocate enough space for service operation of the host machine.
- When options not installed,
- DADF-U1 + Saddle Finisher-AE2 + Puncher Unit-M1 + Buffer Pass Unit-E2 + Paper Deck-Q1
(%RH)
100
[C]
90
85
[B]
75
[A]
70
50
25
20
15
10
5
0
10
15
7.5
100 mm or more
500 mm
or more
20
25
30
35
23
27.5
32.5
F-2-1
1,035 mm
500 mm
or more
F-2-2
40
(degC)
Chapter 2
0019-8444
2-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3225 series3230 series3235 series

Table of Contents