Chapter 17
17.6.1.9 COPIER > OPTION > BODY (9/15)
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
The value which has been set takes effect after the main power switch has been turned OFF and back ON.
Item
Level
DA-PORT
2
DA-CNCT
2
CHNG-STS
2
CHNG-CMD
2
17-118
COPIER > OPTION > BODY
Description
Title
Port setting when DA is installed
Purpose of use, When used
This item is used when DA is installed. (used in Japanese machines only, not used in overseas
machines) Set the port for communication with the DA (Digital Accessory).
Precautions for use
When this item is set to '1', the following items are also set to ON.
COPIER > OPTION > BODY > STS-PORT
Settings and adjustment
0: Closed
ranges
1: Opened (when DA is installed)
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
For future expansion (The setting must not be changed.)
operation procedures
Related service modes
-
Additional description and
-
notes
Title
WPGW connection setting
Purpose of use, When used
Set the WPGW connection. (used in Japanese machines only, not used in overseas machines)
Precautions for use
-
Settings and adjustment
0: OFF
ranges
1: ON
Unit
-
Value at time of shipment
0
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
WPGW : Workplace Gateway
notes
Title
Setting of T.O.T. status connection port number
Purpose of use, When used
This item is used when Service NAVI is used. Set the number of the port used for the status connection
in T.O.T.
Precautions for use
-
Settings and adjustment
1 to 65535
ranges
Unit
-
Value at time of shipment
20010
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes
Title
Setting of T.O.T. command connection port number
Purpose of use, When used
This item is used when Service NAVI is used. Set the number of the port number for the command
connection in T.O.T.
Precautions for use
-
Settings and adjustment
1 to 65535
ranges
Unit
-
Value at time of shipment
20000
from factory/Value
established when RAM is
cleared
Setting, adjustment and
1) Select the item to highlight it, input the setting, and press the OK key.
operation procedures
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
-
notes
T-17-58
> CMD-PORT
> SSH-SW
> DA-PORT