Detecting An Error - Canon iR3245 Series Service Manual

Hide thumbs Also See for iR3245 Series:
Table of Contents

Advertisement

9.4.2 Detecting an Error

iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
Error code
Detail code
E000
0001
E001
0000
0001
0002
E002
0000
E003
0000
E004
0000
E007
0000
E014
0001
0002
Symptom
The fixing temperature fails to increase.
The fixing main thermistor detects
overheating.
A hardware circuit detects overheating.
The fixing sub thermistor detects
overheating.
The fixing temperature fails to reach a
specific level.
The fixing temperature has dropped to an
abnormally low level.
Missing of the thermistor connector
The fixing film rotates in an abnormal
way.
The machine detects a fixing motor error.
(The motor is not locked.)
The machine detects a fixing motor error.
(The motor is unlocked.)
T-9-3
When each of the following conditions is detected for 200 msec or more continuously, the
machine assumes that an error has occurred.
- A temperature of less than 30 deg C is detected by the fixing thermistor after 1 sec since the
start of power supply.
- A temperature of less than 70 deg C is detected by the fixing thermistor after 2 sec since the
start of power supply.
- A temperature of less than 120 deg C is detected by the fixing thermistor after 6 sec since
the start of power supply.
The fixing thermistor detects 250 deg C or more for 200 msec or more continuously.
A hardware circuit detects overheating in relation to the fixing thermistor (main/sub).
The fixing thermistor detects 295 deg C or more for 200 msec or more continuously.
In the course of start-up control, the fixing thermistor detects less than 115 deg C for 400 msec
or more continuously after 1.3 sec since it detected 100 deg C. Or, the fixing thermistor
detects less than 150 deg C for 400 msec or more continuously after 1.3 sec since it detected
140 deg C.
In the course of normal temperature control, the fixing thermistor detects less than 140 deg C
for 200 msec or more continuously.
Missing of the connector is detected for 30 msec continuously.
The reading of the fixing main thermistor is in excess of 100 deg C with the fixing motor in
a locked state and, in addition, the machine fails to detect the marker signal for 6 sec.
The locked status is not detected even when 2 sec elapses after the motor is turned on.
The motor is unlocked for 500 msec continuously after the locked status is detected.
Description
Chapter 9