Make sure to note the followings before installing the host machine.
1) If moving the host machine from the cold place to a warm place abruptly, dew condensation is generated inside host machine and it may cause various image
failures. Thus unpack and place the host machine in warm place for 2 hours or more to accustom the host machine to room temperature before installation.
(Condensation: condensation commonly occurs when a vapor is cooled to a liquid, for example, when metals are moved from a cool place to a warm place,
vapors around metals are cooled into a liquid and attaches to metals.)
2) Since the host machine weighs 97kg at the maximum (including DADF), make sure to lift it with 4 people and also lift it in a horizontal position.