16.29 MITSUBISHI J2-S100

16.29.1 HMI Setting
Communication parameters must be set the same as those of the PLC. The following settings are recommended.
Parameter
Serial I/F port
Baud rate
Parity
Data bits
Stop bits
HMI station No.
PLC station No.
Comm. delay (10msec) 0
16.29.2 J2-S100 Setting
Communication parameters must be the same as those of HMI (See recommendation above).
Compatible with:
MITSUBISHI J2-S100(MR-J2-10C) Servo
16.29.3 Wiring
16.29.3.1
Wiring for cable connections using MITSUBISHI J2-S100 with RS422 MicroD 20 Socket ports.
KEP Part#: (Not Available) (D-Sub 9 Female Plug to MicroD Plug Cable)
HMI PLC[RS-485]
2 RxD+
1 RxD-
4 TxD+
3 TxD-
5 GND
16.29.3.2
Wiring for cable connections using MITSUBISHI J2-S100 with RS232 MicroD 20 Socket ports.
KEP Part#: (Not Available) (D-Sub 9 Male Socket to MicroD Plug Cable)
HMI PLC[RS-232]
2 TxD
3 RxD
5 GND
Note: Graphic representation may not reflect the actual appearance of the finished cable.
Recommended Setting Notes
RS485 4W
9600
Even
8
1
0
0
Connect to MITSUBISHI J2-S100 CN3 RS422 Port
19 SDN-
9 SDP+
15 RDN-
5 RDP+
11 LG
Shield
Earth Ground
Connect to MITSUBISHI J2-S100 CN3 RS232 Port
2 RxD
12 TxD
11 LG
Shield
Earth Ground
Options: RS232, RS485 4W – Dependant on PLC hardware
Options: 9600, 19200 - Must match PLC port setting
Options: Odd, Even, None - Must match PLC port setting
Must match PLC port setting
Must match PLC port setting
Not used
Options: 0~15 - Must match PLC port setting
Request delay: 0~999 @10 milliseconds. Use when the PLC requires a
delay between requests. Not implemented in simulation mode.
261