16.14 IIS ESC (INDUSTRIAL INDEXING SYSTEMS)
16.14.1 HMI Setting
Communication parameters must be set the same as those of the PLC. The following settings are recommended.
Parameter
Recommended Setting
Serial I/F port
RS232
Baud rate
19200
Parity
None
Data bits
8
Stop bits
1
HMI station No.
0
PLC station No.
255
Comm. delay (10msec) 0
16.14.2 Controller Setting
Communication parameters must be the same as those of the MMI.
App Port set Mode: ESC Packet Protocol 19200, None, 8, 1
Compatible PLC
Emerald EMC-2000 controller
16.14.3 Wiring
Wiring for cable connections using Emerald EMC-2000 Controllers with RS232 RJ-12 socket ports.
16.14.3.1
KEP Part#: (Not Available) (D-Sub 9 Male Socket to RJ-12 Male Cable)
HMI PLC[RS-232]
2 TXD
3 RXD
5 GND
Note: Graphic representation may not reflect the actual appearance of the finished cable.
Connect to Emerald EMC-2000 Controller with RS232 Port
3 RXD
5 TXD
4 GND
Shield
Earth Ground
Notes
Options: RS232, RS485 – Dependant on PLC hardware
Options: 9600, 19200, 38400, 57600, 115200 - Must match PLC port
setting
Options: Odd, Even, None - Must match PLC port setting
Options: 7, 8 - Must match PLC port setting
Options: 1, 2 - Must match PLC port setting
Not used
Not used
Request delay: 0~999 @10 milliseconds. Use when the PLC requires a
delay between requests. Not implemented in simulation mode.
232