Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B [SP No. 1-104-028]
No
FUNCTION
Extension access code (0 to
7) to turn V.8 protocol On/Off
0-7
0: On
1: Off
Communication Switch 1C [SP No. 1-104-029]
No
FUNCTION
Extension access code (8 and
9) to turn V.8 protocol On/Off
0-1
0: On
1: Off
2-7 Not used
Communication Switch 1D - Not used (do not change the settings)
Communication Switch 1E - Not used (do not change the settings)
Communication Switch 1F - Not used (do not change the settings)

4.3.5 G3 SWITCHES

G3 Switch 00 [SP No. 1-105-001]
No
FUNCTION
Monitor speaker during
communication (tx and rx)
Bit 1: 0, Bit 0: 0 = Disabled
0
Bit 1: 0, Bit 0: 1 = Up to Phase
1
B
Bit 1: 1, Bit 0: 0 = All the time
Bit 1: 1, Bit 0: 1 = Not used
SM
COMMENTS
If the PABX does not support V.8/V.34 protocol
procedure, set this bit to "1" to disable V.8.
Example: If "0" is the PSTN access code, set bit 0
to 1. When the machine detects "0" as the first
dialed number, it automatically disables V.8
protocol. (Alternatively, if "3" is the PSTN access
code, set bit 3 to 1.)
COMMENTS
Refer to communication switch 1B.
Example: If "8" is the PSTN access code, set bit 0
to 1. When the machine detects "8" as the first
dialed number, it automatically disables V.8
protocol. (If "9" is the PSTN access code, use bit
1.)
Do not change the settings.
COMMENTS
(0, 0): The monitor speaker is disabled all through
the communication.
(0, 1): The monitor speaker is on up to phase B in
the T.30 protocol.
(1, 0): Used for testing. The monitor speaker is on
all through the communication. Make sure that
you reset these bits after testing.
73
Bit Switches
B786