12 July '86

28. Pre-quenching Corona Wire Replacement

1.
Remove the drum cover (2 screws).
2.
Disconnect the high voltage cable [A] from the terminal.
3.
Remove the pre-quenching corona unit [B].
4.
Remove the front and rear endblock covers [C] (1 screw on the rear
Be careful not to break off the side hooks.
cover).
5.
Unhook the spring [D] and remove the old corona wire [E].
6.
Clean the front and rear endblocks and the corona casing.