Transfer And Separation Corona Wire Replacement - Ricoh FT7060 Field Service Manual

Table of Contents

Advertisement

12 July '86

18. Transfer and Separation Corona Wire Replacement

1.
Slide out the fusing unit and remove the transport unit cover (2
screws).
2.
Slide out the transfer and separation corona unit (1 connector).
3.
Remove the front and rear paper guides [A].
4.
Remove the front endblock cover [B] and rear endblock cover [C] (1
screw).
(Be careful not to break off the side hooks.)
5.
Remove the old corona wires.
6.
Clean the front and rear endblocks and corona casing.
7.
Hook the large eyelets [D] of the new corona wires to the front anchor
posts.
8.
Hook the tension springs [E] to the small eyelets and then hook the
tension springs to the rear terminal springs [F]. (Be sure to use the cor-
rect springs as shown in the illustration.)
9.
Check that the wires are in the positioning grooves.
10.
Make sure that the corona wire is between the cleaner pads.
11.
Reassemble.
12.
Check the wire cleaner movement using SP 5-3.