39. Inverter Gate Adjustment

ADJUSTMENT STANDARD: 0.2 mm to 1.0 mm
1.
Pull the fusing unit all the way out and remove the inverter unit cover
[A] (2 screws).
Remove the upper exit roller assembly [B] (2 screws).
2.
3.
Slowly push in the plunger [C] of the inverter gate solenoid [D] until the
return pinch roller [E] touches the return drive roller [F].
At this point, confirm that gap [G] is within specification. If the gap is
4.
not within specification, adjust the inverter gate's position using the two
Allen screws [H].
3-57
12 July '86