SERVICE TABLES

1. Test Points

- Main Board -
Number
Function
TP201
Trigger for P.P. (PCC)
TP202
Trigger for P.P. (PTC)
TP203
Trigger for P.P. (T2)
TP204
T r i g g e r f o r P . P . ( S 2 )
TP205
Reference clock pulse to main motor board
TP206
Reference clock pulse to scanner motor
board
TP207
R e s e t p u l s e
TP208
Reset Pulse
TP209
Clock pulse
TP210
ADS voltage (Adjust using VR201)
TP211
Trigger for P.P. (C)
Trigger for P.P. (T1)
TP212
TP213
T r i g g e r f o r P . P . ( S 1 )
TP214
+24V
TP215
GND
TP216
+15V
+5V
TP217
+1.31 to 1.35V threshold voltage of IC219
TP218
(Adjust using VR202.)
TP219
Trigger for P.P. (PQC)
TP220
Input voltage of image density sensor
(Adjust using VR203.)
-Scanner Motor Control Board-
Number
Function
Scanner ON signal from Main Board
TP501
TP502
Factory Adjustment Use
+4V (Forward): -6V (Reverse)
TP503
TP504
Factory Inspection Use
TP505
Factory Adjustment Use
Factory Adjustment Use
TP506
TP507
Ground (GND)
TP508
Factory Adjustment Use
-Main Motor Control Board-
Number
Function
GND
TP301
TP302
Encoder Pulse Reference (+0.77V)