Pre-Transfer Corona Wire Replacement - Ricoh FT7060 Field Service Manual

Table of Contents

Advertisement

17. Pre-transfer Corona Wire Replacement

1.
Remove the transport unit cover [A] (2 screws).
2.
Remove the pre-transfer corona unit [B] (1 screw and 2 connectors
[C]).
3.
Remove the front endblock cover
[E]. (Be careful not to break off the side hooks.)
4.
Unhook the spring [F] and remove the old corona wire.
5.
Clean the front and rear endblocks and the corona casing.
6.
Hook the large eyelet [G] of the new corona wire to the rear anchor
post
Hook the tension spring to the small eyelet [H]‚ and then hook it to
7.
the front terminal.
8.
Make sure that the corona wire is between the cleaner pads.
9.
Reassemble, then check the wire cleaner movement using SP 5-3.
(1 screw) and rear endblock cover
[D]
3-31