Setting The Fuser Control Temperature; Resetting The Fuser Problem Data - Kyocera TASKalfa 300i Service Manual

Hide thumbs Also See for TASKalfa 300i:
Table of Contents

Advertisement

Maintenance
item No.

Setting the fuser control temperature

U161
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fuser problem on thick paper.
Method
1. Press the start key.
2. Select the item to be set.
3. Change the setting using the +/- or numeric keys.
Display
DRIVE START TEMP
READY CONTROL T
READY CONTROL T2 Fuser edge control temperature for
PRINT CONTROL T
READY DISP TIME
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.

Resetting the fuser problem data

U163
Description
Resets the detection of a service call code indicating a problem in the fuser section.
Purpose
To prevent accidents due to an abnormally high fuser temperature.
Method
1. Press the start key.
2. Press [EXECUTE] on the touch panel.
3. Press the start key. The fuser problem data is initialized.
4. Turn the main power switch off and on.
Description
Description
Driving start temperature when
warm-up starts
Fuser center control temperature for
displaying [Ready for copying.]
displaying [Ready for copying.]
Fuser center control temperature
during printing
Time of period from driving until
Ready is displayed
Setting range
Initial setting
°
110
0 to 255 (
C)
°
165
0 to 255 (
C)
°
155
0 to 255 (
C)
°
165
0 to 255 (
C)
0 to 255 (s)
0
2K5